N2 - PURPOSE: To evaluate the feasibility, efficacy, and tolerance of self-expanding metallic stent insertion under fluoroscopic guidance for palliation of symptoms related to malignant gastroduodenal obstruction. MATERIALS AND METHODS: Seventy-two patients (38 men, 34 women) aged 25-98 years (mean, 62 years) with duodenal (n = 43), antropyloric (n = 13), surgical gastrojejunostomy (n = 10), or pyloroduodenal (n = 6) malignant obstruction were referred for insertion of self-expanding metallic stents over a 6-year period. Stent insertion was performed with use of a peroral or transgastric approach when necessary (n = 11). RESULTS: Stents were successfully inserted in 70 of the 72 patients (97%) and provided symptom relief in 65 patients (90%). Inserted stents were mainly uncovered vascular (n = 55) or enteral (n = 10) Wallstents. One hundred eight stents were initially inserted: one, two, three, or four stents were indicated in 43, 17, nine, and one patient, respectively. Mean follow-up was 119 days (range, 4-513 days). Mean stent patency was 113 days (range, 4-513 days). Mean survival of patients was 120 days. During follow-up, stent obstruction occurred in seven patients as a result of tumoral overgrowth (n = 5) or ingrowth (n = 2). Complications occurred in 12 of the 72 patients (17%), including stent migration (n = 8), stent fracture (n = 1), duodenal perforation (n = 1), and death related to general anesthesia (n = 1). CONCLUSION: Despite a significant complication rate, self-expanding metallic stent insertion under fluoroscopic guidance appears to be a feasible and useful technique in the palliative management of malignant gastroduodenal obstruction.
AB - PURPOSE: To evaluate the feasibility, efficacy, and tolerance of self-expanding metallic stent insertion under fluoroscopic guidance for palliation of symptoms related to malignant gastroduodenal obstruction. MATERIALS AND METHODS: Seventy-two patients (38 men, 34 women) aged 25-98 years (mean, 62 years) with duodenal (n = 43), antropyloric (n = 13), surgical gastrojejunostomy (n = 10), or pyloroduodenal (n = 6) malignant obstruction were referred for insertion of self-expanding metallic stents over a 6-year period. Stent insertion was performed with use of a peroral or transgastric approach when necessary (n = 11). RESULTS: Stents were successfully inserted in 70 of the 72 patients (97%) and provided symptom relief in 65 patients (90%). Inserted stents were mainly uncovered vascular (n = 55) or enteral (n = 10) Wallstents. One hundred eight stents were initially inserted: one, two, three, or four stents were indicated in 43, 17, nine, and one patient, respectively. Mean follow-up was 119 days (range, 4-513 days). Mean stent patency was 113 days (range, 4-513 days). Mean survival of patients was 120 days. During follow-up, stent obstruction occurred in seven patients as a result of tumoral overgrowth (n = 5) or ingrowth (n = 2). Complications occurred in 12 of the 72 patients (17%), including stent migration (n = 8), stent fracture (n = 1), duodenal perforation (n = 1), and death related to general anesthesia (n = 1). CONCLUSION: Despite a significant complication rate, self-expanding metallic stent insertion under fluoroscopic guidance appears to be a feasible and useful technique in the palliative management of malignant gastroduodenal obstruction.
UR - http://www.scopus.com/inward/record.url?scp=14644408705&partnerID=8YFLogxK
U2 - 10.1097/01.RVI.0000145227.90754.76
DO - 10.1097/01.RVI.0000145227.90754.76
M3 - Article
C2 - 15713926
AN - SCOPUS:14644408705
SN - 1051-0443
VL - 16
SP - 247
EP - 253
JO - Journal of Vascular and Interventional Radiology
JF - Journal of Vascular and Interventional Radiology
IS - 2 I
ER -