Résumé
Hickman central venous catheter and venous access ports are widely used in patients with hematology or oncology disorders. However, these long-term venous access devices can be the source of several kinds of complications that may compromise the functional and/or vital patient's prognosis. All these complications must be known, diagnosed, treated and prevented. If there is no consensus concerning the prevention of catheter-related thrombosis, various methods are now available to diagnose, treat and prevent device-related bloodstream infections. Extravasation of corrosive drugs represents a very serious complication of long-term venous access devices. The surgical technique that uses early subcutaneous wash-out in acute extravasation injuries is simple and safe; it helps to reduce the severe sequelae of highly toxic drug extravasation for the patient.
Titre traduit de la contribution | Complications on Hickman central venous catheter and venous access ports |
---|---|
langue originale | Français |
Pages (de - à) | 1281-1289 |
Nombre de pages | 9 |
journal | Revue du Praticien |
Volume | 56 |
Numéro de publication | 12 |
état | Publié - 30 juin 2006 |