TY - JOUR
T1 - Diagnosis of catheter-related bacteraemia
T2 - A prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures
AU - Blot, François
AU - Nitenberg, Gérard E.
AU - Chachaty, Elisabeth
AU - Raynard, Bruno
AU - Germann, Nathalie
AU - Antoun, Sami
AU - Laplanche, Agnés
AU - Brun-Buisson, Christian
AU - Tancrède, Cyrille
PY - 1999/9/25
Y1 - 1999/9/25
N2 - Background. A method of diagnosing catheter-related infection (CRI) without removing the catheter would be useful. An earlier positivity of central compared with peripheral venous-blood cultures may be associated with catheter-related bacteraemia. We evaluated prospectively the differential time to positivity (DTP) of paired blood cultures drawn simultaneously via the catheter hub and from a peripheral venous site. Methods. Over a 14-month period in an intensive-care unit of a cancer referral centre, simultaneous hub-blood and peripheral-blood cultures (a mean of two per patient) were obtained from patients with a suspected CRI. According to clinical criteria and quantitative culture of the catheter tip, cases were classified as CRI or sepsis of other origin. At least one pair of hub-blood and peripheral-blood cultures was obtained within 48 h before catheter removal, and were recorded the DTP between hub-blood and peripheral-blood cultures with an automatic device for detection of blood culture positivity. Findings. We analysed 93 catheters removed because of suspicion of CRI. In 28 episodes, the same micro-organisms were found in both hub-blood and peripheral-blood cultures. A diagnosis of definite bacteraemic CRI was made in 16 of the 17 patients in whom a positive hub-blood culture was detected at least 2 hours earlier than peripheral-blood culture. About half (9/17) of these episodes occurred in long-term (> 30 days) devices. CRI was excluded in ten of the 11 patients with a DTP lower than 2 h. The DTP of paired blood cultures was significantly greater in patients with CRI than in others (p < 10-4). A cut-off DTP value of 120 min had 91% specificity and 94% sensitivity for the diagnosis of CRI. Three of 17 episodes with only hub-blood culture positive were associated with CRI., Interpretation This prospective study suggests that measurement of the differential time to positivity between hub-blood and peripheral-blood cultures is a simple and reliable tool for in-situ diagnosis of catheter-related sepsis in cancer patients. Further studies are needed to confirm these data for short-term catheters.
AB - Background. A method of diagnosing catheter-related infection (CRI) without removing the catheter would be useful. An earlier positivity of central compared with peripheral venous-blood cultures may be associated with catheter-related bacteraemia. We evaluated prospectively the differential time to positivity (DTP) of paired blood cultures drawn simultaneously via the catheter hub and from a peripheral venous site. Methods. Over a 14-month period in an intensive-care unit of a cancer referral centre, simultaneous hub-blood and peripheral-blood cultures (a mean of two per patient) were obtained from patients with a suspected CRI. According to clinical criteria and quantitative culture of the catheter tip, cases were classified as CRI or sepsis of other origin. At least one pair of hub-blood and peripheral-blood cultures was obtained within 48 h before catheter removal, and were recorded the DTP between hub-blood and peripheral-blood cultures with an automatic device for detection of blood culture positivity. Findings. We analysed 93 catheters removed because of suspicion of CRI. In 28 episodes, the same micro-organisms were found in both hub-blood and peripheral-blood cultures. A diagnosis of definite bacteraemic CRI was made in 16 of the 17 patients in whom a positive hub-blood culture was detected at least 2 hours earlier than peripheral-blood culture. About half (9/17) of these episodes occurred in long-term (> 30 days) devices. CRI was excluded in ten of the 11 patients with a DTP lower than 2 h. The DTP of paired blood cultures was significantly greater in patients with CRI than in others (p < 10-4). A cut-off DTP value of 120 min had 91% specificity and 94% sensitivity for the diagnosis of CRI. Three of 17 episodes with only hub-blood culture positive were associated with CRI., Interpretation This prospective study suggests that measurement of the differential time to positivity between hub-blood and peripheral-blood cultures is a simple and reliable tool for in-situ diagnosis of catheter-related sepsis in cancer patients. Further studies are needed to confirm these data for short-term catheters.
UR - http://www.scopus.com/inward/record.url?scp=0040562485&partnerID=8YFLogxK
U2 - 10.1016/S0140-6736(98)11134-0
DO - 10.1016/S0140-6736(98)11134-0
M3 - Comment/debate
C2 - 10509498
AN - SCOPUS:0040562485
SN - 0140-6736
VL - 354
SP - 1071
EP - 1077
JO - The Lancet
JF - The Lancet
IS - 9184
ER -