Evaluation of oxaliplatin exposure of healthcare workers during heated intraperitoneal perioperative chemotherapy (HIPEC)

Antoine F. Villa, Souleiman El Balkhi, Radia Aboura, Herve Sageot, Helene Hasni-Pichard, Marc Pocard, Dominique Elias, Nathalie Joly, Didier Payen, François Blot, Joel Poupon, Robert Garnier

    Résultats de recherche: Contribution à un journalArticleRevue par des pairs

    42 Citations (Scopus)

    Résumé

    The aim of this study was to evaluate air and surface contaminations, and internal contamination of healthcare workers during open-abdomen HIPEC using oxaliplatin. Platinum (Pt) was measured in urine of exposed workers and in multiple air and surface samples. Three successive HIPEC procedures were investigated in each of the two hospitals participating in the study. Analysis of air samples did not detect any oxaliplatin contamination. Heavy contamination of the operating table, the foor at the surgeon’s feet, and the surgeon’s overshoes were observed. Hand contamination was observed in surgeons using double gloves for intra-abdominal chemotherapy administration, but not in those using three sets of gloves. Pt was not detected in urine samples obtained after HIPEC (<5 ng/L). The main risk of HIPEC is related to direct or indirect skin exposure and can be prevented by correct use of adapted protective equipment.

    langue originaleAnglais
    Pages (de - à)28-37
    Nombre de pages10
    journalIndustrial Health
    Volume53
    Numéro de publication1
    Les DOIs
    étatPublié - 1 janv. 2015

    Contient cette citation