TY - JOUR
T1 - Intraoperative ultrasonography during percutaneous Achilles tendon repair
AU - Soubeyrand, Marc
AU - Serra-Tosio, Géraldine
AU - Campagna, Raphael
AU - Molina, Véronique
AU - Sitbon, Philippe
AU - Biau, David J.
PY - 2010/12/1
Y1 - 2010/12/1
N2 - Background: The purpose of the study was to determine whether real-time intraoperative ultrasonography improved implant positioning and stump approximation in patients with acute Achilles tendon rupture managed percutaneously. Materials and Methods: The needles were introduced percutaneously without ultrasonography and their position was checked relative to cutaneous landmarks and by palpation. Then, intraoperative ultrasonography was performed to assess needle position at the proximal tendon segment, tendon tear, and distal tendon segment. Incorrectly placed needles were removed and reinserted under real-time ultrasonographic guidance. Tendon apposition was checked ultrasonographically. Results: We included 21 patients (19 males, two females) with unilateral acute Achilles tendon rupture, in whom 42 needles (one medial and one lateral) were inserted. Correct positioning was achieved without ultrasonographic guidance for 19 (45%) needles overall, 15 of 21 (71%) medial needles, and four of 21 (19%) lateral needles. The remaining 23 needles were correctly repositioned under ultrasonographic guidance. The correct positioning rates with and without ultrasonography differed significantly for all needles (p < 0.0001) and for lateral needles (p < 0.0001) but not for medial needles (p = 0.03). Intraoperative ultrasonography confirmed tendon stump approximation in all cases. Conclusion: Without imaging, 55% of needles were correctly positioned. Intraoperative ultrasonography allowed correct positioning of all needles and provided intraoperative confirmation of stump approximation.
AB - Background: The purpose of the study was to determine whether real-time intraoperative ultrasonography improved implant positioning and stump approximation in patients with acute Achilles tendon rupture managed percutaneously. Materials and Methods: The needles were introduced percutaneously without ultrasonography and their position was checked relative to cutaneous landmarks and by palpation. Then, intraoperative ultrasonography was performed to assess needle position at the proximal tendon segment, tendon tear, and distal tendon segment. Incorrectly placed needles were removed and reinserted under real-time ultrasonographic guidance. Tendon apposition was checked ultrasonographically. Results: We included 21 patients (19 males, two females) with unilateral acute Achilles tendon rupture, in whom 42 needles (one medial and one lateral) were inserted. Correct positioning was achieved without ultrasonographic guidance for 19 (45%) needles overall, 15 of 21 (71%) medial needles, and four of 21 (19%) lateral needles. The remaining 23 needles were correctly repositioned under ultrasonographic guidance. The correct positioning rates with and without ultrasonography differed significantly for all needles (p < 0.0001) and for lateral needles (p < 0.0001) but not for medial needles (p = 0.03). Intraoperative ultrasonography confirmed tendon stump approximation in all cases. Conclusion: Without imaging, 55% of needles were correctly positioned. Intraoperative ultrasonography allowed correct positioning of all needles and provided intraoperative confirmation of stump approximation.
KW - Mini-Invasive
KW - Repair
KW - Surgery
KW - Tendon
UR - http://www.scopus.com/inward/record.url?scp=78650322294&partnerID=8YFLogxK
U2 - 10.3113/FAI.2010.1069
DO - 10.3113/FAI.2010.1069
M3 - Article
C2 - 21189207
AN - SCOPUS:78650322294
SN - 1071-1007
VL - 31
SP - 1069
EP - 1074
JO - Foot and Ankle International
JF - Foot and Ankle International
IS - 12
ER -