Tumor mutational burden assessment in non-small-cell lung cancer samples: Results from the TMB 2 harmonization project comparing three NGS panels

Javier Ramos-Paradas, Susana Hernández-Prieto, David Lora, Elena Sanchez, Aranzazu Rosado, Tamara Caniego-Casas, Nuria Carrizo, Ana Belén Enguita, María Teresa Muñoz-Jimenez, Borja Rodriguez, Urbicio Perez-Gonzalez, David Gómez-Sánchez, Irene Ferrer, Santiago Ponce Aix, Ángel Nuñez Buiza, Pilar Garrido, José Palacios, Fernando Lopez-Rios, Eva M. Garrido-Martin, Luis Paz-Ares

Résultats de recherche: Contribution à un journalArticleRevue par des pairs

22 Citations (Scopus)

Résumé

Background Tumor mutational burden (TMB) is a recently proposed predictive biomarker for immunotherapy in solid tumors, including non-small cell lung cancer (NSCLC). Available assays for TMB determination differ in horizontal coverage, gene content and algorithms, leading to discrepancies in results, impacting patient selection. A harmonization study of TMB assessment with available assays in a cohort of patients with NSCLC is urgently needed. Methods We evaluated the TMB assessment obtained with two marketed next generation sequencing panels: TruSight Oncology 500 (TSO500) and Oncomine Tumor Mutation Load (OTML) versus a reference assay (Foundation One, FO) in 96 NSCLC samples. Additionally, we studied the level of agreement among the three methods with respect to PD-L1 expression in tumors, checked the level of different immune infiltrates versus TMB, and performed an inter-laboratory reproducibility study. Finally, adjusted cut-off values were determined. Results Both panels showed strong agreement with FO, with concordance correlation coefficients (CCC) of 0.933 (95% CI 0.908 to 0.959) for TSO500 and 0.881 (95% CI 0.840 to 0.922) for OTML. The corresponding CCCs were 0.951 (TSO500-FO) and 0.919 (OTML-FO) in tumors with <1% of cells expressing PD-L1 (PD-L1<1%; N=55), and 0.861 (TSO500-FO) and 0.722 (OTML-FO) in tumors with PD-L1≥1% (N=41). Inter-laboratory reproducibility analyses showed higher reproducibility with TSO500. No significant differences were found in terms of immune infiltration versus TMB. Adjusted cut-off values corresponding to 10 muts/Mb with FO needed to be lowered to 7.847 muts/Mb (TSO500) and 8.380 muts/Mb (OTML) to ensure a sensitivity >88%. With these cut-offs, the positive predictive value was 78.57% (95% CI 67.82 to 89.32) and the negative predictive value was 87.50% (95% CI 77.25 to 97.75) for TSO500, while for OTML they were 73.33% (95% CI 62.14 to 84.52) and 86.11% (95% CI 74.81 to 97.41), respectively. Conclusions Both panels exhibited robust analytical performances for TMB assessment, with stronger concordances in patients with negative PD-L1 expression. TSO500 showed a higher inter-laboratory reproducibility. The cut-offs for each assay were lowered to optimal overlap with FO.

langue originaleAnglais
Numéro d'articlee001904
journalJournal for ImmunoTherapy of Cancer
Volume9
Numéro de publication5
Les DOIs
étatPublié - 7 mai 2021
Modification externeOui

Contient cette citation