N2 - The purpose of this study was to evaluate the accuracy of high-frequency ultrasound (US) in the preoperative assessment of skin tumors. A US scanner with a 20-MHz probe was used to visualize and evaluate 70 skin lesions (38 clinically suspected melanomas and 32 suspected basilar cell carcinomas [BCCs]) before surgical resection. A US morphologic study and a Doppler analysis of vascularity were performed for each tumor. Of the 70 tumors, 62 were clearly visualized, including 19 melanomas, 12 nonmalignant nevi, and 31 BCCs. Most lesions were hypoechoic. In 13 of 19 proved melanomas, the difference between the histologic and US measurements was equal to or less than 0.2 mm. Vessels were visualized in melanomas with thicknesses greater than 3 mm. All BCCs were visualized, and in 29% of cases of BCC, tumor size at US was greater than that at clinical examination. High-frequency, high-resolution US is a simple, reliable, noninvasive method for accurate preoperative assessment of skin tumor dimensions. This technique allows surgical planning to be adapted and reexcision to be avoided. However, its role is limited in the differential diagnosis of malignant and benign skin lesions.
AB - The purpose of this study was to evaluate the accuracy of high-frequency ultrasound (US) in the preoperative assessment of skin tumors. A US scanner with a 20-MHz probe was used to visualize and evaluate 70 skin lesions (38 clinically suspected melanomas and 32 suspected basilar cell carcinomas [BCCs]) before surgical resection. A US morphologic study and a Doppler analysis of vascularity were performed for each tumor. Of the 70 tumors, 62 were clearly visualized, including 19 melanomas, 12 nonmalignant nevi, and 31 BCCs. Most lesions were hypoechoic. In 13 of 19 proved melanomas, the difference between the histologic and US measurements was equal to or less than 0.2 mm. Vessels were visualized in melanomas with thicknesses greater than 3 mm. All BCCs were visualized, and in 29% of cases of BCC, tumor size at US was greater than that at clinical examination. High-frequency, high-resolution US is a simple, reliable, noninvasive method for accurate preoperative assessment of skin tumor dimensions. This technique allows surgical planning to be adapted and reexcision to be avoided. However, its role is limited in the differential diagnosis of malignant and benign skin lesions.
KW - Melanoma, .32
KW - Skin, US, .1298
KW - Skin, neoplasms, .32
UR - http://www.scopus.com/inward/record.url?scp=0031261499&partnerID=8YFLogxK
U2 - 10.1148/radiographics.17.6.9397463
DO - 10.1148/radiographics.17.6.9397463
M3 - Article
C2 - 9397463
AN - SCOPUS:0031261499
SN - 0271-5333
VL - 17
SP - 1559
EP - 1565
JO - Radiographics
JF - Radiographics
IS - 6
ER -